top of page
Pro AV Catalog
Manufacturers
PRODUCT CATEGORIES
Matching Keywords
Model Numbers
Control Systems : Related Control Systems Products : Network Technologies Inc (NTI) - E-MICRO-TRHP-TAA
Request Quote
All Products
Micro Environment Monitoring System, Integrated Temp/Humidity Sensor, POE. Power supply NOT included. TAA compliant.
Series: ENVIROMUX®
Model: E-MICRO-TRHP-TAA
- Dual DC power provides dual redundancy.
- Sensors supported by a single E-MICRO: 1 integrated temperature/humidity combination sensor. 2 RJ45 ports for external temperature/humidity sensors. 2 digital inputs sensitive to contact closure.
- Available with optional built-in Power over Ethernet.
- Sensors are hot pluggable.
- Monitor (ping) up to 4 IP network devices – alerts are sent if devices are not responding.
Product Info
Tech Specs
Related Products
Documents
The ENVIROMUX® Micro Environment Monitoring System (EMS) monitors critical environmental conditions, such as temperature, humidity, liquid water presence, power, intrusion, and smoke. When a sensor goes out of range of a configurable threshold, the system will notify you via email, web page, network management (SNMP), and/or SMS messages (via email-to-SMS).
The system functions independently or as an IP-connected remote sensor for the E-2D/5D/16D. It features an integrated temperature/humidity sensor, two RJ45 sensor ports for external temperature/humidity sensors, two dry contact inputs and optional built-in Power over Ethernet (PoE).
For more information, visit: http://www.networktechinc.com/environment-monitor-micro.html
- Dual DC power provides dual redundancy.
- Sensors supported by a single E-MICRO: 1 integrated temperature/humidity combination sensor. 2 RJ45 ports for external temperature/humidity sensors. 2 digital inputs sensitive to contact closure.
- Available with optional built-in Power over Ethernet.
- Sensors are hot pluggable.
- Monitor (ping) up to 4 IP network devices – alerts are sent if devices are not responding.
- Create multiple alerts for any installed sensor.
- Sensor conditions can be configured to trigger alerts by themselves, and/or be used in combination with other alerts to trigger one Smart Alert. Configure up to 32 alerts, and one Smart Alert.
- Alerts are posted in message log, which is accessible through Web user interface.
- Supports NTI's IP network video cameras for live view of any facility.
- Integrates with various Open Source SNMP monitoring packages – Nagios. The unit can be polled via SNMP.
- Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 ENVIROMUX units and all connected sensors. Choose between Enterprise Management Software or Low-Cost Management Software.
- Optional iOS App or Android App provides an easy-to-use interface for monitoring sensor statuses and acknowledging/dismissing sensor alerts from an unlimited number of E-MICRO units.
- Security: HTTPS, TLS v1.2, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
- Integrated mounting brackets for easy surface/wall mounting. Optional DIN mounting available.
- Use in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, or any unmanned area that needs to be monitored.
- Use the E-MICRO-TRH(P) with a wireless router and Wi-Fi Range Extender to create a Wireless Environment Monitoring System. Configure, monitor, and receive alerts without the use of a wired network connection.
- ROHS Compliant - Yes
- Systems Controlled - Other
- Warranty - Yes
- Spec Sheet available - Yes
- Depth: 3.44 in
- Height: 1.37 in
- Power: Built-in Power over Ethernet and dual DC power provides triple redundancy. Power over Ethernet standards supported: IEEE 802.3af, 802.3at. Proprietary schemes such as Cisco Discovery Protocol are not supported. Similar legacy switches and routers will have to use PWR-SPLY-ELC. If the first power source fails, the unit will automatically, without interruption, switch over to the second power source. The unit draws power from the source with the highest DC voltage (nominal 5.5V). If two or more sources have exactly the same voltage, it will draw in part from each of them. 110 to 240 VAC at 50 or 60 Hz via AC adapter (not included). Country-specific AC adapters sold separately (PWR-SPLY-ELC). Input voltage: 5.5VDC ±5%. Power consumption: 4W max. Use the PWR-48V-5-5V4A DC-DC power converter to install the E-MICRO in a 48V or 24V Telecom environment.
- Width: 4 in
- MTBF: E-MICRO-TRHP: 577,812 hours.
- Dimensions: WxDxH in (all options): 4x3.44x1.37 (102x87x35 mm). Includes mounting holes to match rack hole spacing.
- Regulatory Compliance: TAA compliant
- Protocols: HTTP/HTTPS, SNMP V1/V2c/V3, SMTP, TCP/IP, Syslog, SNTP, DHCP, TLS v1.2, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour. Compatible with any SNMP management software. The unit can be polled via SNMP. Operates and configures via HTTP/HTTPS web page. Supports Internet Explorer 6.0 and higher, Firefox 1.5 and higher, Netscape 9, Google Chrome, Safari 1.3 and higher for MAC, and Safari 3.0 and higher for PC. Multiplatform support: Windows 2000/XP/Vista/7/8/10, Windows Server 2000/2003/2008/2012/2016/2019, Solaris, Linux, FreeBSD, and MAC OS 9/10. An IP address can be assigned to the E-MICRO automatically by a DHCP server. Generates SNMP traps, email alerts, syslog messages, and SMS messages (via email-to-SMS). Alerts are posted in event log, which is accessible through Web user interface. Email alerts can be sent to 9 addresses. Users can configure the schedule for when they will be alerted. Supports HTTP REST API to poll sensor data with response in JSON format.
- Environmental: Operating & Storage Temperature: -4 to 185°F (-20 to 85°C). Operating & Storage Relative Humidity: 0 to 99% non-condensing RH.
- USB Port: One female Micro USB connector for connecting a USB Modem.
- DC Voltage: 5.50 Volts
- Web Interface: Supports Internet Explorer 6.0 and higher, Firefox 1.5 and higher, Netscape 9, Google Chrome, Safari 1.3 and higher for MAC, and Safari 3.0 and higher for PC. Configure sensor thresholds, alarm methods, formats of alerts, and system data log. View/edit entries stored in the system logs. The data log can be downloaded as a comma-separated plain text file. Configure IP information (address, subnet mask, default gateway, DNS, etc.), user administrative settings, and data logging settings. Up to 9 users can access the web page at one time. Permissions, schedule and alert methods are configurable for each user. Configure up to 32 sensor conditions (alerts). Configure 1 Smart Alert to use different alert combinations to send alert messages.
- Telnet: Monitor over the text-based menu system accessible via Telnet. Access is controlled via username/password. System stores encrypted login information. Two user levels: user and administrator.
- Active Power: 4 Watt
- Warranty (Length/Type): Two years.
- Dry Contact Closures: Two screw terminal pairs for connecting dry contact devices and the liquid detection sensor.
- Certifications: CE, RoHS
- RJ45 Sensor Ports: Two RJ45 modular jacks for connecting temperature sensors, humidity sensors, or combined temperature/humidity sensors. Three levels of user-defined alerts – normal, warning, critical.
- Operating Temperature (Maximum): 185 F
- Operating Temperature (Minimum): -4 F
- AC Voltage (Minimum): 110 Volts
- AC Voltage (Maximum): 240 Volts
- Network Operation: SNMP support, allowing integration into network management platforms. Updating the system firmware.
- Web Interface: Configuration can be done over the Internet/LAN via Web page.: When connected as an IP remote sensor for an E-2D/5D/16D unit, the E-MICRO is configured via the E-xD web interface.
- Web Interface: View/edit sensors' current values, thresholds and alert statuses.: All sensors connected to the ENVIROMUX-MICRO can be viewed on one summary page. User configurable settings allow sensors to return to normal status when alert condition clears, without manually acknowledging/dismissing the alert.
- Web Interface: Event log records system alerts.: Stores up to 200 entries.
- Web Interface: Data log records samples of sensor readings per minute.: Stores up to 43,000 entries per sensor.
- Open Source Monitoring Integration: SNMP Plugin for Nagios. Using Multi Router Traffic Grapher. Data Logging using Syslog.
- Optional Management Software: Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 ENVIROMUX units and all connected sensors. Push configuration changes to multiple connected units in a group at once. E.g. new users, mail server, network settings, security settings, system settings, etc. Choose between Enterprise Management Software or Low-Cost Management Software. E-MNG Enterprise Management Software – use to monitor and configure up to 3,000 E-2D/5D/16D, E-MICRO-TRH(P), E-1W(P), E-SEMS-16(U), IPDU-S4/8 units and all connected sensors. E-MNG-LC Low-Cost Management Software – use to monitor and configure up to 3,000 E-MICRO-TRH(P) and E-1W(P) units and all connected sensors.
- Optional Android App for Tablet/Phone: Optional Android App provides an easy-to-use interface for monitoring sensor statuses and acknowledging/dismissing sensor alerts from many E-MICRO units.
- Integrated Temperature/Humidity Sensor: Applications from -4 to 167°F (-20 to 75°C) and 0 to 90% relative humidity. Temperature accuracy (in moving air – minimum airflow 8.2 ft/s (2.5 m/s)): ±0.72°F at 14 to 167°F (±0.4°C at -10 to 75°C). ±0.9°F at -4 to 14°F (±0.5°C at -20 to -10°C). Resolution: 0.2°F (0.1°C). Humidity accuracy: 0 to 80% relative humidity, ±3%. 80 to 90% relative humidity, ±4%.
E-16D
- Large Enterprise Environment Monitoring System. Power: AC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-24V
- Large Enterprise Environment Monitoring System. Power: 24VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-24VDP
- Large Enterprise Environment Monitoring System. Power: Dual 24VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-48V
- Large Enterprise Environment Monitoring System. Power: 48VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-48VDP
- Large Enterprise Environment Monitoring System. Power: Dual 48VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16DDP
- Large Enterprise Environment Monitoring System. Power: Dual AC. Logging: 1,000 data log entries; 1,000 event log entries.
E-2D
- Small Enterprise Environment Monitoring System
E-2D-D
- Small Enterprise Environment Monitoring System, DIN Mounted
E-2DB
- Small Enterprise Environment Monitoring System, Back-up Battery
E-2DB-D
- Small Enterprise Environment Monitoring System, Back-up Battery, DIN Mounted
E-5D
- Medium Enterprise Environment Monitoring System
E-5D-48V
- Medium Enterprise Environment Monitoring System, 48VDC Power
E-5D-D
- Medium Enterprise Environment Monitoring System, DIN Mounted
E-5DB
- Medium Enterprise Environment Monitoring System, Back-up Battery
E-5DB-D
- Medium Enterprise Environment Monitoring System, Back-up Battery, DIN Mounted
E-5DB-IND
- Industrial Medium Enterprise Environment Monitoring System for High Temperature Environments, Back-up Batter
E-IPCAM-HNPO-P
- Ultra-HD Wired Day/Night Outdoor Bullet IP Camera with Power over Ethernet (POE)
E-MICRO-T
- Micro Environment Monitoring System /Remote Temperature Sensor over IP
E-MICRO - Application Drawing
59 kb
- Other
How to send SMS Alert Messages without using a USB modem and SIM Card
166736 kb
- Other
E-MICRO - Data Sheet
340751 kb
- Data Sheet
E-MICRO-T.step – 3D image file
12333048 kb
- Other
E-MICRO-T.step – 3D image file
12333043 kb
- Other
Download new firmware and MIB files
58831 kb
- Other
Micro Server Environment Monitoring System
13974 kb
- Other
E-MICRO-T(RHP): Customer Testimonials
25849 kb
- Other
E-MICRO - Installation & Operation Manual
2965152 kb
- Instructions
Video: How to Configure Email Notifications When Using Gmail
4314 kb
- Instructions
E-MICRO-T(RHP) – Quick Installation Guide
135711 kb
- Instructions
Request Quote
Thank you!
Someone will be in touch with you shortly.
Contact USIS AV
close
USIS AV
35 West Jefferson Ave
Pearl River, NY 10965
USA
(845) 358-7755
https://www.usisav.net/
Contact in regards to this product:
Network Technologies Inc (NTI)
Model: E-MICRO-TRHP-TAA
Request more information from a dealer near you
close
Request more information from a dealer near you
bottom of page