Secure Remote Power Control Unit with Environmental Monitoring
Model: IPDU-S2
- Three operating modes for power reboot: Manual – select the outlet and turn the power on/off. Scheduled – set date/time/duration of power cycle. Associated – power on/off a device when a sensor goes out of range of a user-defined threshold, or reboot unresponsive IP devices.
- Security: HTTPS, SSHv2, SSLv3, TLS (4/8-port models only), IP Filtering, LDAPv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
- Configure, control and monitor the unit via Web interface or Command Line Interface (CLI).
- Up to 3 additional IP aliases can be configured to allow remote control of the unit using different networks. No scripts required - simply add the IP address, network mask, and gateway configurations through the web interface. The first network (default network) will be used for total control of the unit, i.e. inbound and outbound connections. The three other networks will allow web/SSH/telnet access only, i.e. inbound access only. Up to four separate networks can be plugged into a network switch that is linked to the unit to facilitate the configuration.
- Current, line voltage, line frequency, power factor monitoring (4/8-port models only).
Product Info
Tech Specs
Related Products
Documents
Accessories
The ENVIROMUX® Secure Remote Power Control Unit allows you to remotely reboot and control power (on/off) to up to eight servers or other powered devices from any location via secure web interface, RS232, SSH, or Telnet.
Available sensors
Web Interface ( view product demo)
Open Source Monitoring Integration
Stencil Drawing:
Firmware:
Knowledge Base:
Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 ENVIROMUX-2D/5D/16D, ENVIROMUX-SEMS-16(U), IPDU-S4/8 units and all connected sensors.
Learn more about Graphing Critical Environment Conditions with MRTG here: http://www.networktechinc.com/ipdu-s-mrtg-app.html
- Three operating modes for power reboot: Manual – select the outlet and turn the power on/off. Scheduled – set date/time/duration of power cycle. Associated – power on/off a device when a sensor goes out of range of a user-defined threshold, or reboot unresponsive IP devices.
- Security: HTTPS, SSHv2, SSLv3, TLS (4/8-port models only), IP Filtering, LDAPv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
- Configure, control and monitor the unit via Web interface or Command Line Interface (CLI).
- Up to 3 additional IP aliases can be configured to allow remote control of the unit using different networks. No scripts required - simply add the IP address, network mask, and gateway configurations through the web interface. The first network (default network) will be used for total control of the unit, i.e. inbound and outbound connections. The three other networks will allow web/SSH/telnet access only, i.e. inbound access only. Up to four separate networks can be plugged into a network switch that is linked to the unit to facilitate the configuration.
- Current, line voltage, line frequency, power factor monitoring (4/8-port models only).
- Monitor (ping) up to eight IP network devices. Supports two environmental sensors, including: temperature/humidity and water detection.
- Sends alert notifications via email, syslog, LEDs, Web page, and SNMP.
- Automatically configures network settings received from a connected DHCP server. If a DHCP server is not found, the default static IP address will be used.
- Integrates with various Open Source monitoring packages - Nagios and MRTG. The unit can be polled via SNMP.
- Up to 17 units can be connected via Ethernet connection or using CAT5 expansion cables to increase the number of outlets and sensors connected (4- and 8-port models only). Cascade up to 16 IPDU-Sx units as slaves to one IPDU-Sx master unit via Ethernet connection. Each master and slave unit needs its own unique IP address. Cascade up to 16 IPDU-Sx units as slaves to one IPDU-Sx master unit using CAT5/5e/6 patch cables with RJ45 connectors wired straight through. Each slave unit needs its own unique RS485 address value that can range from 1-255. Uses a single Web interface for all systems/sensors connected.
- Overload protection via circuit breaker (4/8-port models only).
- Meets the electrostatic discharge (ESD) immunity requirements of IEC/EN 61000-4-2
- Features Normally Open (NO) relay contacts. The 4/8-port units are available with optional Normally Closed (NC) relay contacts.
- Optional industrial unit for harsh environments at temperatures from -40° to 158°F (-40° to 70°C).
- ROHS Compliant - Yes
- Warranty - Yes
- Spec Sheet available - Yes
- Power: 90 to 250 VAC at 50 to 60 Hz. Power consumption: 2.7W max. Input Connector: IPDU-S2: IEC 320-C14 inlet. IPDU-Sx-P15(-OT3): NEMA 5-15P line cord (US) IPDU-Sx-P10(-OT3): IEC 320-C14 inlet (EURO). Output Connectors: IEC C13 outlets. IPDU-S2: IEC 320-C13 outlets. IPDU-Sx-P15(-OT3): NEMA 5-15R outlets (US). IPDU-Sx-P10(-OT3): IEC 320-C13 outlets (EURO).
- Current Rating: Input/Output: 10A. Location: All.
- RJ45 Sensor Ports: Two RJ45 modular jacks for connecting NTI temperature/humidity and liquid detection sensors.
- Network Interface: One 10/100 Base-T Ethernet port with RJ45 Ethernet connector.
- Console Port: One female RJ45 port for terminal access.
- Cascade In/Out Ports (4/8-Port Models): Two RJ45 jacks. A maximum of 17 systems can be used in a cascaded configuration via RS485 to increase the number of outlets and sensor ports (1 master, 16 slaves). Each slave unit needs its own unique RS485 address value that can range from 1-255. Use CAT5/5e/6 patch cables with RJ45 connectors wired straight through Up to 1,000 feet between the master unit and the slave unit. The last slave must have a terminating plug (ENVIROMUX-TRMPLG, not included) in the empty socket.
- USB Port (4/8-Port Models): Female USB Type A connector for downloading log data to USB flash drive.
- MTBF: 183,724 hrs
- Protocols: HTTPS, SSHv2, SSLv3, TLS (4/8-port models only), LDAPv3, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour, SNMPv2c; IP filtering, IPV6 Operates and configures via HTTP/HTTPS web page, Telnet, SSH, or RS232 interface. Alerts are sent using email, syslog, and/or SNMP traps. Alerts are posted in event log, which is accessible through Web user interface.
- Operating Temperature (Maximum): 122 F
- Operating Temperature (Minimum): 32 F
- Certifications: CE, RoHS, EN51055, EN50121-3-2
- Storage Temperature: -13 to 149°F (-25 to 65°C).
- Warranty (Length/Type): Two years
- AC Voltage (Maximum): 250 Volts
- AC Voltage (Minimum): 90 Volts
- Depth: 5.55 in
- Height: 1.40 in
- Width: 6.12 in
E-MNG-0010
- Enterprise Server Environment Monitoring System Management Software: 10 units
E-MNG-0050
- Enterprise Server Environment Monitoring System Management Software: 50 units
E-MNG-0100
- Enterprise Server Environment Monitoring System Management Software: 100 units
E-MNG-0500
- Enterprise Server Environment Monitoring System Management Software: 500 units
E-MNG-3000
- Enterprise Server Environment Monitoring System Management Software: 3,000 units
E-STHS-99
- Temperature/Wide Range Humidity/Dew Point Sensor
E-STS
- Temperature Sensor
IPDU-S4-NC-P10
- Secure Remote Power Control Unit with Environmental Monitoring
IPDU-S4-NC-P15
- Secure Remote Power Control Unit with Environmental Monitoring
IPDU-S4-P10
- Secure Remote Power Control Unit with Environmental Monitoring
IPDU-S4-P15
- Secure Remote Power Control Unit with Environmental Monitoring
IPDU-S8-NC-P10
- Secure Remote Power Control Unit with Environmental Monitoring
IPDU-S8-NC-P15
- Secure Remote Power Control Unit with Environmental Monitoring
IPDU-S8-P10
- Secure Remote Power Control Unit with Environmental Monitoring
IPDU-S8-P15
- Secure Remote Power Control Unit with Environmental Monitoring
How to Use LDAP Server with the IPDU-Sx
183352 kb
- Instructions
How to Create an x.509 Certificate
72407 kb
- Instructions
IPDU-2 — Declaration of Conformity
174346 kb
- Other
Secure Remote Power Control Unit with Environmental Monitoring
30433 kb
- Other
How to Provide a Redundant Path to Control the IPDU-Sx In Case of a Network Failure
106339 kb
- Other
Secure Remote Power Control Unit with Environmental Monitoring
317683 kb
- Data Sheet
IPDU-Sx — Installation Manual
4833118 kb
- Instructions
Request Quote
Thank you!
Someone will be in touch with you shortly.
Contact USIS AV
close
USIS AV
35 West Jefferson Ave
Pearl River, NY 10965
USA
(845) 358-7755
https://www.usisav.net/