AC Power Monitor with Relay, US/Canada, 220 Volts, 18A rated load, 20A maximum
Series: ENVIROMUX
Model: E-ACLM-P18-V2
- Reports AC Voltage, Frequency, Power, and Current. Monitors Power from one AC inlet to one AC outlet, between 50~250VAC and 47~63Hz. Monitors the number of swells, sags, and spikes. Monitors swell and sag duration of 0.1 second to 1 minute.
- Includes Relay with configurable disconnect settings: threshold reboot, or manual reboot.
- Capable of measuring current surges from 300 mA to 20A.
- User defined minimum and maximum voltage and power thresholds.
- Capable of detecting user selected spike events with a peak greater than 50V, 250V, 500V, or 1KV.
Product Info
Tech Specs
Related Products
Documents
Environment Monitoring System AC & DC Power Monitors
Power Relays & Sensors compatible with ENVIROMUX® E-2D, E-5D and E-16D
For more information, visit https://www.networktechinc.com/ac-power-monitor.html
- Reports AC Voltage, Frequency, Power, and Current. Monitors Power from one AC inlet to one AC outlet, between 50~250VAC and 47~63Hz. Monitors the number of swells, sags, and spikes. Monitors swell and sag duration of 0.1 second to 1 minute.
- Includes Relay with configurable disconnect settings: threshold reboot, or manual reboot.
- Capable of measuring current surges from 300 mA to 20A.
- User defined minimum and maximum voltage and power thresholds.
- Capable of detecting user selected spike events with a peak greater than 50V, 250V, 500V, or 1KV.
- Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). E-2D/5D: supports CAT5/5e/6 cable up to 750 ft (229 m).
- Powered by E-2D/5D/16D.
- Compatible with E-FSC Fiber Converter/Extender. Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.
- ROHS Compliant - Yes
- Warranty - Yes
- Certifications: CE, RoHS
- Depth: 6.50 in
- Height: 1.65 in
- Width: 7 in
- Warranty (Length/Type): Two years
- Accuracy: Voltage accuracy: ±1% FS at 32 to 104°F (0 to 40°C). Frequency accuracy: ± 1% Current accuracy: ± 2.7%
- Outlet Max load rating (continuous): (US/Canada): 18A rated load, 20A maximum.
- Cables Included: one L6-20r to IEC 320 C20, and one L6-20p to IEC 320 C19.
- Weight: 1.6 lbs (726 g).
- Current Consumption: 13mA @ 5VDC, 125mA @ 12VDC.
- Operating Temperature (Maximum): 104 F
- Operating Temperature (Minimum): 32 F
E-16D
- Large Enterprise Environment Monitoring System. Power: AC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-24V
- Large Enterprise Environment Monitoring System. Power: 24VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-24VDP
- Large Enterprise Environment Monitoring System. Power: Dual 24VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-48V
- Large Enterprise Environment Monitoring System. Power: 48VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-48VDP
- Large Enterprise Environment Monitoring System. Power: Dual 48VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16DDP
- Large Enterprise Environment Monitoring System. Power: Dual AC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16DEL
- Large Enterprise Environment Monitoring System. Power: AC. Logging: 1,200,000 data log entries; 3,000 event log entries.
E-2D
- Small Enterprise Environment Monitoring System
E-2D-24V
- Small Enterprise Environment Monitoring System, 24VDC Power
E-2D-D
- Small Enterprise Environment Monitoring System, DIN Mounted
E-2DB
- Small Enterprise Environment Monitoring System, Back-up Battery
E-2DB-D
- Small Enterprise Environment Monitoring System, Back-up Battery, DIN Mounted
E-5D
- Medium Enterprise Environment Monitoring System
E-5D-48V
- Medium Enterprise Environment Monitoring System, 48VDC Power
E-5D-D
- Medium Enterprise Environment Monitoring System, DIN Mounted
E-5D-IND48VLT
- Industrial Medium Enterprise Environment Monitoring System, 48VDC Power
E-5D-INDLT
- Industrial Medium Enterprise Environment Monitoring System
E-5DB
- Medium Enterprise Environment Monitoring System, Back-up Battery
E-5DB-D
- Medium Enterprise Environment Monitoring System, Back-up Battery, DIN Mounted
E-5DB-IND
- Industrial Medium Enterprise Environment Monitoring System for High Temperature Environments, Back-up Batter
E-ACLM-P12-V2
- AC Power Monitor with Relay, US/Canada, 110 Volts, 12A rated load, 15A maximum
E-ACLM-P8-V2
- AC Power Monitor with Relay, Euro/UK, 220 Volts, 8A rated load, 10A maximum
E-ACLM-xx-V2 — Installation Manual
781747 kb
- Instructions
Request Quote
Thank you!
Someone will be in touch with you shortly.
Contact USIS AV
close
USIS AV
35 West Jefferson Ave
Pearl River, NY 10965
USA
(845) 358-7755
https://www.usisav.net/
Contact in regards to this product:
Network Technologies Inc (NTI)
Model: E-ACLM-P18-V2
Request more information from a dealer near you
close
Request more information from a dealer near you
bottom of page