Large Enterprise Environment Monitoring System. Power: 48VDC. Logging: 1,000 data log entries; 1,000 event log entries.
Series: ENVIROMUX®
Model: E-16D-48V
- Monitor and manage server room environmental and security conditions over IP.
- Sensors supported: 16 external configurable sensors; 8 digital inputs sensitive to contact closure; 8 Remote Temperature/Humidity Sensors over IP; 3 internal sensors – temperature, humidity, power.
- Four output relays for control of external devices.
- Relay activates upon alarm or via the user interface.
- Control output relays via SNMP SET commands to power on/off external devices.
The ENVIROMUX® Enterprise Environment Monitoring System monitors critical environmental conditions, such as temperature, humidity, liquid water presence, power, intrusion, and smoke. When a sensor goes out of range of a configurable threshold, the system will notify you via email, LEDs, alarm beacon, siren, web page, network management (SNMP), voice phone calls (via Automatic Voice Dialer System), and SMS messages (via external USB 3G modem). The system includes three internal sensors: temperature, humidity and power. It also supports 16 external configurable sensors, eight digital input sensors, and four output relays for control of external devices. For more information, visit http://www.networktechinc.com/environment-monitor-16d.html#tab-9
- Monitor and manage server room environmental and security conditions over IP.
- Sensors supported: 16 external configurable sensors; 8 digital inputs sensitive to contact closure; 8 Remote Temperature/Humidity Sensors over IP; 3 internal sensors – temperature, humidity, power.
- Four output relays for control of external devices.
- Relay activates upon alarm or via the user interface.
- Control output relays via SNMP SET commands to power on/off external devices.
- Supports IP network video cameras for live view of any facility.
- One integrated view – see different Web cameras side-by-side with physical and environmental parameters.
- Any programmed event can trigger a snapshot from an IP camera.
- Monitor (ping) up to 64 IP network devices.
- Alerts are sent if devices are not responding
- Linux inside.
- Create multiple alerts for any installed sensor.
- Sensor conditions (events) can be configured to trigger alerts by themselves, and/or be used in combination with other events to trigger Smart Alerts.
- Configure up to 50 events. Setup SSH commands to be sent when events are triggered to soft shutdown or reboot machines.
- Up to 20 Smart Alerts can be configured to use different event combinations to send alert messages.
- View entries stored in the system logs. Event log records system events such as alerts, user login/logout, failed email messages, etc. Data log records samples of sensor readings. User specified sampling time period. With E-16D, both the event log and the data log store up to 1,000 entries. With E-16DEL, up to 1,200,000 data log entries and 3,000 event log entries are stored. 256 MB non-volatile memory - both the data log and event log persist after power cycle.
- Automatically configures network settings received from a connected DHCP server.
- If a DHCP server is not found, the default static IP address will be used.
- Integrates with various Open Source monitoring packages – Nagios and MRTG. The unit can be polled via SNMP.
- USB ports for connecting USB modem or for downloading log data to USB flash drive.
- Internal battery backup.
- Alerts are sent when there is a power outage and when power returns.
- Available with optional dual power for connection to two separate power sources.
- Up to five units can be connected via Ethernet connection or using CAT5 expansion cables to increase the number of sensors connected.
- Cascade up to four E-2D/5D/16D units as slaves to one E-2D/5D/16D master unit via Ethernet connection.
- Each master and slave unit needs its own unique IP address.
- Cascade up to four E-16D units as slaves to one E-16D master unit using CAT5/5e/6 patch cables with RJ45 connectors wired straight through.
- Each slave unit needs its own unique RS485 address value that can range from 1-255.
- Uses a single Web interface for all systems/sensors connected.
- Available with optional 48VDC or 24VDC power.
- Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 E-2D/5D/16D, ENVIROMUX-SEMS-16(U), IPDU-S4/8 units and all connected sensors.
- 1RU rack mount case is standard.
- The ENVIROMUX system can be mounted so that the sensor connectors are facing the front or back of the rack.
- Security: HTTPS, SSHv2, SSLv3, IP Filtering, LDAPv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
- Use in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, or any unmanned area that needs to be monitored.
- Systems Controlled - Other
- Warranty - Yes
- ROHS Compliant - Yes
- Spec Sheet available - Yes
- Power Port: Power consumption: 35W Connection for Earth Ground. Fuse protection. Optional 48VDC power (not shown). Accepts 36~72VDC (48VDC nominal).
- RJ45 Sensor Ports: Sixteen RJ45 modular jacks for connecting NTI temperature, humidity, temperature/humidity, liquid detection, smoke detection, glass break, vibration and motion sensors.
- Digital Inputs: Eight screw terminals pairs for connecting dry contact devices. Input voltage: 0VDC to +25VDC. Provides +12VDC, 50 mA. Fuse protection.
- Digital Outputs: Four screw terminals pairs. Potential-free relay switch contacts. Normally open / normally closed connection points. Maximum switching load: 0.5A at 100VAC, 1A at 30VDC, 0.5A at 48VDC.
- Beacon Port: One screw terminal pair. Provides +12VDC, 180 mA to supply an alarm beacon. Fuse protection
- Siren Port: One screw terminal pair. Provides +12VDC, 180 mA to supply a siren. Fuse protection
- Aux Power: One screw terminal pair. Provides +12 VDC, 150 mA.
- USB Device Ports: Four female USB Type A connectors for connecting USB modem, for downloading log data to USB flash drive, or for connecting a USB LCD screen. Two USB ports on front panel and 2 on back panel.
- USB Console Port: One female USB Type B connector for connecting a PC for serial terminal access.
- RS232 (DCS) Port: One female RJ45 serial port for terminal access.
- Ethernet Port: One 10/100 Base-T Ethernet port with RJ45 Ethernet connector. Supports full- and half-duplex.
- Protocols: HTTP/HTTPS, SNMP V1/V2c/V3, SMTP, TCP/IP, Syslog, SNTP, DHCP, SSHv2, SSLv3, TLS v1.2, LDAPv3, XOAUTH2, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour, IPV6, WAP 2.0, RADIUS Support for XOAUTH2 provides higher security authentication for email accounts (e.g. Gmail). Compatible with any SNMP management software. The unit can be polled via SNMP. Operates and configures via HTTP/HTTPS web page, Telnet, SSH, or USB/RJ45 serial interface. An IP address can be assigned to the E-16D automatically by a DHCP server. Generates SNMP traps, email alerts, syslog messages, and SMS messages (via USB 3G modem). Alerts are posted in event log, which is accessible through Web user interface. Email alerts can be sent to 17 addresses. Users can configure the schedule for when they will be alerted, as well as customize the e-mail subject line for each sensor alert. SNMP traps have unique OID's (Object Identifiers) for each sensor. OIDs for sensor and contact values for E-16D. Supports HTTP REST API to poll sensor data with response in JSON format.
- Internal Temperature Sensor: For monitoring the temperature inside the E-16D case. Use an external temperature sensor for monitoring ambient air temperature. Applications from 32 to 104°F (0 to 40°C). Accurate to within ±1.35°F (±0.75°C).
- Internal Humidity Sensor: For monitoring the humidity inside the E-16D case. Use an external humidity sensor for monitoring humidity in the air. Applications from 20% to 80% relative humidity at temperatures between 32 to 104°F (0 to 40°C). Accurate to within ±5% relative humidity.
- Internal Power Sensor: Measures voltage on 48VDC models: 36 to 72VDC. Measures battery voltage: 0 to 20 VDC. Alerts are sent when there is a power outage and when power returns.
- Back-up Battery: Rechargeable sealed lead-acid battery. Provides back-up for one hour.
- Dimensions: WxDxH (in): Without supplied rackmount kit : 16.19x10.01x1.75. With supplied rackmount kit: 19x10.01x1.75.
- Environmental: Operating temperature: 32 to 104°F (0 to 40°C). Storage temperature: -22 to 140°F (-30 to 60°C). Operating /Storage Relative Humidity: 17 to 90% non-condensing RH.
- Regulatory Approvals: CE, RoHS.
- Warranty (Length/Type): Two years.
- RS232 AUX Port: One RJ45 port for connecting a serial GSM modem or a remote serially-controlled device.
- Cascade IN/OUT Ports: Two RJ45 jacks. A maximum of 5 systems can be used in a cascaded configuration via RS485 to increase the number of sensor ports (1 master, 4 slaves). Each slave unit needs its own unique RS485 address value that can range from 1-255. Use CAT5/5e/6 patch cables with RJ45 connectors wired straight through Up to 4,000 feet between the master unit and the slave unit. The last slave must have a terminating plug (ENVIROMUX-TRMPLG, not included) in the empty socket. Uses a single Web interface for all systems connected.
- Operating Temperature (Maximum): 104 F
- Operating Temperature (Minimum): 32 F
- Certifications: CE, RoHS
- DC Voltage: 48 Volts
- Depth: 10.01 in
- Height: 1.75 in
- Width: 16.19 in
- Regulatory Compliance: CE, RoHS
Extension Rail Kit
E-SLDO-IP68
IP68 Submersible Spot Liquid Detector
E-APP-ANROID
Enterprise Server Environment Monitoring System Android App
USIS AV
35 West Jefferson Ave
Pearl River, NY 10965
USA
(845) 358-7755
https://www.usisav.net/