High-Accuracy Platinum RTD Transmitter, -328°F to 1562°F
Model: E-RTDT-1562
- Use to connect 100O platinum RTD temperature sensors to the E-2D/5D/16D.
- Accurate to within ±0.2°F (±0.1°C). If the connected RTD sensor does not support this high of accuracy, the system will revert to the accuracy of the sensor.
- Interfaces with the E-2D/5D/16D via the RJ45 sensor port. Includes 7 ft pre-wired RJ45 cable with attached coupler to extend the transmitter up to 1000 feet (328 m) using CATx cable.
- Din rail mount housing.
- Includes pre-stripped country-specific line cord with tinned strands.
Product Info
Tech Specs
Related Products
Documents
Server Environment Monitoring System RTD Sensors
RTD Temperature Sensors & Transmitters compatible with E-2D, E-5D and E-16D
For more information, visit http://www.networktechinc.com/rtd-temperature-sensor.html#sensors
- Use to connect 100O platinum RTD temperature sensors to the E-2D/5D/16D.
- Accurate to within ±0.2°F (±0.1°C). If the connected RTD sensor does not support this high of accuracy, the system will revert to the accuracy of the sensor.
- Interfaces with the E-2D/5D/16D via the RJ45 sensor port. Includes 7 ft pre-wired RJ45 cable with attached coupler to extend the transmitter up to 1000 feet (328 m) using CATx cable.
- Din rail mount housing.
- Includes pre-stripped country-specific line cord with tinned strands.
- Warranty - Yes
- Spec Sheet available - Yes
- Operating Temperature (Maximum): 131 F
- Operating Temperature (Minimum): 32 F
- Depth: 4.09 in
- Height: 0.89 in
- Width: 5.08 in
- Warranty (Length/Type): Two years
- Temperature Range: -328 to 1562°F (-200 to 850°C). When used with the E-2D/5D/16D, the supported range is -89 to 738°F (-67 to 392°C. Call an NTI product consultant to have the range expanded on the ENVIROMUX system.
- Configuration: 2, 3, or 4-wire connection
- Signal Output: 4-20 mA
- Storage Temperature: -40 to 185°F (-40 to 85°C).
E-16D
- Large Enterprise Environment Monitoring System. Power: AC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-24V
- Large Enterprise Environment Monitoring System. Power: 24VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-24VDP
- Large Enterprise Environment Monitoring System. Power: Dual 24VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-48V
- Large Enterprise Environment Monitoring System. Power: 48VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-48VDP
- Large Enterprise Environment Monitoring System. Power: Dual 48VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16DDP
- Large Enterprise Environment Monitoring System. Power: Dual AC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16DEL
- Large Enterprise Environment Monitoring System. Power: AC. Logging: 1,200,000 data log entries; 3,000 event log entries.
E-2D
- Small Enterprise Environment Monitoring System
E-2D-24V
- Small Enterprise Environment Monitoring System, 24VDC Power
E-2D-D
- Small Enterprise Environment Monitoring System, DIN Mounted
E-2DB
- Small Enterprise Environment Monitoring System, Back-up Battery
E-2DB-D
- Small Enterprise Environment Monitoring System, Back-up Battery, DIN Mounted
E-5D
- Medium Enterprise Environment Monitoring System
E-5D-48V
- Medium Enterprise Environment Monitoring System, 48VDC Power
E-5D-D
- Medium Enterprise Environment Monitoring System, DIN Mounted
E-5D-IND48VLT
- Industrial Medium Enterprise Environment Monitoring System, 48VDC Power
E-5D-INDLT
- Industrial Medium Enterprise Environment Monitoring System
E-5DB
- Medium Enterprise Environment Monitoring System, Back-up Battery
E-5DB-D
- Medium Enterprise Environment Monitoring System, Back-up Battery, DIN Mounted
E-5DB-IND
- Industrial Medium Enterprise Environment Monitoring System for High Temperature Environments, Back-up Batter
E-RTDS-A221
- All-Purpose 100 Ohm RTD Sensor, -67°F to 221°F
E-RTDS-A392
- All-Purpose 100 Ohm RTD Sensor, -58 to 392°F
E-RTDS-D240
- Duct 100 Ohm RTD Sensor, -67°F to 240°F
E-RTDS-E140
- Encapsulated 100 Ohm RTD Sensor, 35°F to 140°F
E-RTDS-ER230
- Rugged Encapsulated 100 Ohm RTD Sensor, -30°F to 230°F
E-RTDS-MP240
- Mini Probe 100 Ohm RTD Sensor, -67°F to 240°F
E-RTDS-PAR540-12IN
- Pipe 100 Ohm RTD Sensor with Adjustable Ring, -58°F to +540°F, 6" to 12"
E-RTDS-PAR540-2IN
- Pipe 100 Ohm RTD Sensor with Adjustable Ring, -58°F to +540°F, 1.25" to 2"
E-RTDS-PAR540-6IN
- Pipe 100 Ohm RTD Sensor with Adjustable Ring, -58°F to +540°F, 2" to 6"
E-S420MA-24V
- 4-20mA Sensor Converter
Application Note: Connect the E-RTDT-1562 Transmitter and RTD sensor to the E-2D/5D/16D
36558 kb
- Instructions
Installation Manual
679787 kb
- Instructions
Data Sheet
627492 kb
- Data Sheet
Request Quote
Thank you!
Someone will be in touch with you shortly.
Contact USIS AV
close
USIS AV
35 West Jefferson Ave
Pearl River, NY 10965
USA
(845) 358-7755
https://www.usisav.net/
Contact in regards to this product:
Network Technologies Inc (NTI)
Model: E-RTDT-1562
Request more information from a dealer near you
close
Request more information from a dealer near you
bottom of page